Free Nov-2024 UPDATED Blue Prism AD01 Certification Exam Dumps is Online
Blue Prism Exam 2024 AD01 Dumps Updated Questions
NEW QUESTION # 12
Examine the following diagram which has been extracted from a Blue Prism Process currently being tested in Process Studio
The Request Type is a text data item and will contain a text value which categorizes the type of request being processed. The Process Request stage has been assigned a Breakpoint with the following Breakpoint condition:
What will happen if you press the Go button when debugging the Process?
- A. If the 'Request Type' value equals "New Card", then the Process will stop at the Breakpoint on the
'Process Request' stage - B. Breakpoints are unconditional therefore the Process flow will always stop at the 'Process Request' stage
- C. If the 'Request Type' value equals "New Card" then the Process will flow to the End stage without stopping
- D. If the 'Request Type' value is not equal to "New Card", then the Process will stop at the Breakpoint on the 'Process Request' stage
Answer: A
Explanation:
* Understanding the Breakpoint:
* A breakpoint in Blue Prism is used to pause the execution of a process at a specific stage, allowing for debugging.
* The breakpoint can be conditional, meaning it will only pause the process if a specified condition is met.
* Analyzing the Breakpoint Condition:
* The provided condition is [Request Type] = "New Card".
* This means the breakpoint on the 'Process Request' stage will only trigger if the value of the
'Request Type' data item is "New Card".
* Possible Outcomes:
* Option A: Correct. If the 'Request Type' value equals "New Card", the process will stop at the
'Process Request' stage because the condition is met.
* Option B: Incorrect. If the 'Request Type' value equals "New Card", the process will stop at the breakpoint, not flow to the end without stopping.
* Option C: Incorrect. Breakpoints can be conditional, so they do not always stop the process unconditionally.
* Option D: Incorrect. The process will stop at the breakpoint if the 'Request Type' value equals
"New Card", not if it does not equal "New Card".
* Conclusion:
* The correct answer is A. If the 'Request Type' value equals "New Card", then the process will stop at the breakpoint on the 'Process Request' stage.
References:
* Blue Prism Developer Documentation: Debugging and Breakpoints
* Blue Prism Training Material on Conditional Breakpoints
NEW QUESTION # 13
Study the following configuration




Which of the following statements is correct?
- A. When the configuration is run in Control Room, it will become stuck in an infinite loop
- B. When the configuration is run in Control Room, it will become stuck in an infinite loop until the 'Switch' Session Variable is changed to True in System Manager
- C. When the configuration is run in Control Room, it will become stuck in an infinite loop until the 'Switch' Session Variable is changed to True in the Control Room
- D. When the configuration is run in Control Room, it will fail with an internal error on the first execution of the 'Switch?' stage with the error: Decision did not result in a yes/no
Answer: C
Explanation:
Environment variables value will only be change when the next time process runs and the session variables will change immediately on change in control room.
Session variables values will only be change from the control room and the env variables is only change from the system manager.
NEW QUESTION # 14
Consider the following diagram from an object studio action:
What is the problem with this flow?
- A. The Exception Block should be removed from the page so that all exceptions on that page can be recovered.
- B. There is nothing wrong with the object flow shown in this image.
- C. There is a risk of the flow causing an infinite loop
- D. There should be a wait stage at the end of the flow, before the end stage to ensure the flow logic has worked correctly
Answer: C
NEW QUESTION # 15
Study the following image showing pan: of the flow within a process:
- A. If an exception is thrown in the Cancel Reservation page and is allowed to bubble up to be caught by the Recover stage, the Create Reservation action won't be retried.
- B. There is a missing Resume stage on one of the routes through the flow.
- C. The Retry Count is not being incremented for each retry.
- D. There is a missing Recover stage on one of the routes through the flow.
Answer: A,C
NEW QUESTION # 16 



What will be the outcome after the page has run?
- A. An Internal Exception will be thrown
- B. Data Item Output Value contains B
- C. Data Item Output Value contains C
- D. Data Item Output Value contains A
Answer: D
NEW QUESTION # 17
When designing a Blue Prism solution a Blue Prism architect must respect the requirement that no customer data is visible within the Blue Prism database.
Consider these possible design alternatives:
1. No customer data in the work queue
2. Encrypt the data in the work queue
3. Switch off all stage parameter logging
Which combination of the above will guarantee that no customer data is visible in the Blue Prism log file?
- A. None
- B. 1 and 3
- C. 1 only
- D. 2 and 3
Answer: D
Explanation:
Explanation/Reference:
NEW QUESTION # 18
Which of the following Stages can be found in Process Studio AND Object Studio?
A)
B)
C)
D)
- A. Option A
- B. Option B
- C. Option C
- D. Option D
Reason: Only the choice stage is found in both process and object studio rest all other stages are found only in the object studio.
Answer: B
NEW QUESTION # 19
Consider the following process flow:
Decision "A" properties are:
Decision "B" properties are:
Decision "C" properties are:
What will happen when the process runs?
- A. The flow will pass through calculation stage "C"
- B. An exception will be thrown
- C. The flow will pass through calculation stage "B"
- D. The flow will pass through calculation stage "A"
Answer: C
NEW QUESTION # 20
The Order System application has been successfully launched and Blue Prism has navigated the application to the following screen:
There is a requirement to ensure this screen is in focus before any further interfacing is done with the screen.
Which is the correct configuration to ensure the New Order screen is in focus?
A)
B)
C)
D)
- A. Exhibit B
- B. Exhibit D
For window application to ensure the new screen is in focus We need to activate the New screen as not the application. - C. Exhibit C
- D. Exhibit A
Answer: B
NEW QUESTION # 21
If you change an environment variable when will the new value be available to the process?
- A. Next time a new case is taken from a WQ
- B. Next time resource PC starts
- C. Next time the process starts
- D. Immediately
Answer: A
NEW QUESTION # 22
A Blue Prism solution works fine when developing and testing it in Process and Object studio but when it is run in Control Room exceptions occur because of screen elements not being found.
What is the most likely cause?
- A. The most likely cause for the errors is that the Object Studio action has not been published and therefore cannot be used by the Process in control room.
- B. The most likely cause for the errors is that your application has changed.
- C. The most likely cause for the exceptions is that best practice exception handling has not been incorporated into the Process.
- D. The most likely cause for the errors seen in Control Room is that best practice use of wait stages has not been followed.
Answer: D
NEW QUESTION # 23
Consider the following process flow from a sub-page of a process:
What is the problem with this sub-page flow?
- A. The exception stage within the flow should be removed and replaced with an End stage that returns the found data item as an output parameter.
- B. For better visibility of the process logic the flow steps shown in the image should be on the main page rather than in a sub-page of the process.
- C. There is nothing wrong with the sub-page flow shown in this image.
- D. The sub-page process flow is missing any retry exception handling that should exist where a process calls object actions that interface with an application.
Answer: C
NEW QUESTION # 24
Consider the following process flow from the Main Page of a process in Process Studio:

Thinking about the standard Blue Prism Process Templates, what is wrong with this Main Page process flow?
- A. There is nothing wrong with the Main Page flow shown in the image, it is a copy of Blue Prism's standard Process Template
- B. The Reset Global Data page is not required because sub-page within a process should always use input parameter rather than global data items. There should be no global data to reset.
- C. The Mam Page process flow is too high level For better visibility of the process logic the flow steps hidden m the sub-pages should al be on the main page instead.
- D. The Stop? decision stage should be removed from the process flow, as Stop time is Configured either within the Scheduler process are stopped via Control Room.
- E. There is no exception handling on this Main Page so any exceptions that "bubble up" will cause the process to terminate rather than exceptions being handled correctly.
Answer: E
NEW QUESTION # 25
Study the following page in a process:
The calculation stages contain the following:
What will be the outcome after the page has run?
- A. Data Item Output Value contains A
- B. An Internal Exception will be thrown
- C. Data Item Output Value contains B
- D. Data Item Output Value contains C
Answer: B
NEW QUESTION # 26
Which of the following indicates a case in a Work Queue is waiting to be worked?
A:
B:
C:
D:
- A. Option A
- B. Option D
- C. Option B
- D. Option C
Answer: D
NEW QUESTION # 27
A Blue Prism solution works fine when developing and testing it in Process and Object studio but when it is ran in Control Room exceptions occur because of screen elements not being found. What is the most likely cause?
- A. The most likely cause for the errors is that the Object Studio action has not been published and therefore cannot be used by the Process in control room.
- B. The most likely cause for the errors is that your application has changed.
- C. The most likely cause for the exceptions is that best practice exception handling has not been incorporated into the Process.
- D. The most likely cause for the errors seen in Control Room is that best practice use of wait stages has not been followed.
Answer: D
Explanation:
Explanation
Reason: This is because when we are running the process in testing and development phase at time the speed of running the process is slow, that's why it ran properly and when we haven't give the proper wait stage and when the process ran in control room the exception occurs as the process ran in full speed so the process is not having the time to wait.
This is mentioned in the Process creation exercise or Lifecycle exercise.
NEW QUESTION # 28
You identify an element in Application Modeller and it highlights uniquely and can be used in your object flow diagram. The next day you find that Blue Prism cannot no longer identify the same element, your object flow is giving you 'Element not found' exceptions.
Which of the following statements is true?
- A. It is common for consistency issues to be found during configuration/development testing. The most likely cause is that an attribute has been selected for the element that is changeable, such as a window title with a date, or a URL. The developer needs to ensure that any changeable attributes are unticked.
- B. The Blue Prism product support team should be contacted to report the issue. This signifies an inconsistency in how the Blue Prism product is working which needs to be fixed.
- C. This suggests that Best Practice exception handling has not been implemented in the object. A retry loop around the object stages that are using the element will probably fix the problem.
- D. This must be an environment issue. The Blue Prism environment must be consistent and persistent, and an element that worked one day and does not work the next day suggests the environment is changeable. The IT team supporting the environment needs to be contacted to fix the problem.
Answer: A
Explanation:
Explanation
NEW QUESTION # 29
......
Blue Prism Certified AD01 Dumps Questions Valid AD01 Materials: https://www.prep4away.com/Blue-Prism-certification/braindumps.AD01.ete.file.html
Get The Most Updated AD01 Dumps To Blue Prism Developer Certification: https://drive.google.com/open?id=1Oxg9ffoQ4LQO9BW_7nATt1qtK6aF_0x2