NSE 6 Network Security Specialist Certification NSE6_FSW-7.2 Sample Questions Reliable
Prepare for the Actual NSE 6 Network Security Specialist NSE6_FSW-7.2 Exam Practice Materials Collection
Fortinet NSE6_FSW-7.2 exam is an industry-recognized certification that validates the skills of network professionals in configuring, managing, and troubleshooting FortiSwitch products. NSE6_FSW-7.2 exam covers a wide range of topics related to FortiSwitch products, and candidates must have experience working with these products before attempting the exam. Passing the NSE6_FSW-7.2 exam demonstrates that a network professional has the knowledge and skills required to ensure the security and performance of their network infrastructure.
NEW QUESTION # 12
Exhibit.
LAG and MCLAG are used to increase the available network bandwidth and enable redundancy. How does spanning tree protocol see MCLAG and LAG if they are configured based on the physi-cal view shown in the exhibit? (Choose two)
- A. Switch 3 and Switch 4 uplinks are treated as single interfaces.
- B. Switch 3 and switch 4 are seen as one MCLAG switch client
- C. Switch 1 and Switch 2 both seen as one single switch.
- D. Switch 1. Switch 2, and Switch 3 are seen as one MCLAG peer group
Answer: B,C
NEW QUESTION # 13
How does FortiSwitch perform actions on ingress and egress traffic using the access control list (ACL)?
- A. FortiSwitch checks ACL policies only from top to bottom.
- B. Classifiers enable matching traffic based only on the VLAN ID.
- C. ACL can be used only at the prelookup stage in the traffic processing pipeline.
- D. Only high-end FortiSwitch models support ACL.
Answer: A
NEW QUESTION # 14
Which packet capture method allows FortiSwitch to capture traffic on trunks and management interfaces?
- A. TCP dump
- B. Sniffer profile
- C. SPAN
- D. sFlow
Answer: D
NEW QUESTION # 15
Which two statements about the FortiLink authorization process are true? (Choose two.)
- A. FortiSwitch requires a reboot to complete the authorization process.
- B. A FortiLink frame is sent by FortiGate to FortiSwitch to complete the authorization.
- C. The administrator must manually pre-authorize FortiGate on FortiSwitch by adding the FortiGate serial number.
- D. FortiLink authorization sets the FortiSwitch management mode to FortiLink.
Answer: B,D
NEW QUESTION # 16
What feature can network administrators use to segment network operations and the administration of managed FortiSwitch devices on FortiGate?
- A. FortiGate clustering protocol
- B. FortiLink split interface
- C. FortiGate multi-tenancy
- D. Multi-chassis link aggregation trunk
Answer: C
NEW QUESTION # 17
Which two statements about 802.1X authentication on FortiSwitch ports are true? (Choose two.)
- A. A local user database must be used to authenticate devices using the 802.1X authentica-tion protocol.
- B. All hosts behind an authenticated port are allowed access after a successful authentica-tion.
- C. All devices connecting to FortiSwitch must support 802.1X authentication.
- D. A security policy is used to apply 802.1 authentication on a port.
Answer: B,D
NEW QUESTION # 18
Refer to the exhibit.
The exhibit shows the current status of the ports on the managed FortiSwitch. Access-1.
Why would FortiGate display a serial number in the Native VLAN column associated with the port23 entry?
- A. Ports connected to adjacent FortiSwitch devices show their serial number as the native VLAN.
- B. port23 is configured as the dedicated management interface.
- C. A standalone switch with the shown serial number is connected on port23.
- D. port23 is a member of a trunk that uses the Access-1 FortiSwitch serial number as the name of the trunk.
Answer: C
NEW QUESTION # 19
Which Ethernet frame can create Layer 2 flooding due to all bytes on the destination MAC address being set to all FF?
- A. The anycast Ethernet frame
- B. The broadcast Ethernet frame
- C. The multicast Ethernet frame
- D. The unicast Ethernet frame
Answer: B
NEW QUESTION # 20
Refer to the exhibits.

You are asked to ensure that managed FortiSwitch devices are reachable by other devices, such as SNMP and other management tools across your network.
Which setting must you configure to ensure traffic from other devices in the network reaches FortiSwitch?
- A. Enable NAC settings to select the onboarding VLAN.
- B. Select a specific default gateway provided to FortiSwitch as an upstream device.
- C. Recreate the FortiLink interface with a nonaggregate setting.
- D. Change the FortiLink interface IP address and DHCP server address range.
Answer: D
NEW QUESTION # 21
Which statement about using MAC, IP, and protocol-based VLANs on FortiSwitch is true?
- A. It provides benefits that can be obtained when using 802.1X authentication.
- B. Endpoints are required to use the same FortiSwitch port to remain members of the VLAN.
- C. FortiSwitch uses only the Ethernet type to assign traffic to VLANs.
- D. lt is a scalable and secure solution in comparison to other Layer 2 security measures.
Answer: A
NEW QUESTION # 22
What can an administrator do to maintain the existing standalone FortlSwltch configuration while changing the management mode to FortLink?
- A. Use a migration tool based on python script to convert the configuration
- B. Register FortiSwitch to For1ISwitch Cloud to save a copy before managing by Forti-Gate.
- C. FortiGate will automatically save the existing FortiSwitch configuration during the Forti-link management process.
- D. Enable the Forti-link setting on FortiSwitch before the authorization process
Answer: D
NEW QUESTION # 23
Refer to the exhibits

Traffic arriving on port2 on FortiSwitch is tagged with VLAN ID 10 and destined for PC1 connected on port1. PC1 expects to receive traffic untagged from port1 on FortiSwitch.
Which two configurations can you perform on FortiSwitch to ensure PC1 receives untagged traffic on port1? (Choose two.)
- A. Remove VLAN 10 from the allowed VLANs and add it to untagged VLANs on port1.
- B. Enable Private VLAN on VLAN 10 and add VLAN 20 as an isolated VLAN.
- C. Add the MAC address of PCI as a member of VLAN 10.
- D. Add VLAN ID 10 as a member of the untagged VLANs on port1.
Answer: C,D
NEW QUESTION # 24
Exhibit.
port1 and port2 are the only ports configured with the same native VLAN 10.
What are two reasons that can trigger port1 to shut down? (Choose two.)
- A. Loop guard frame sourced from port 1 was received VLAN 10 ports.
- B. An endpoint sent BPDU on port1 it received from another interface.
- C. Oport1 was shut down by loop guard protection.
- D. STP triggered a loop and applied loop guard protection on port1.
Answer: A,C
NEW QUESTION # 25
Which statement about the IGMP snooping querier when enabled on a VLAN is true?
- A. IGMP reports on the VLAN are forwarded to all switch ports.
- B. All other indirectly connected switches will be unable to get IGMP multicast traffic.
- C. Active multicast receiver entries are aging on each IGMP query sent on the VLAN
- D. The setting can only be enabled using the FortiSwitch CLI.
Answer: B
NEW QUESTION # 26
Refer to the exhibit.
Core-1 and Access-1 are managed and authorized by FortiGate-1. which uses port4 as the FortiLink interface. After FortiGate authorizes and manages Core-2. Port1 status becomes STP discarding.
Why is port1 in the discarding state?
- A. Core-1 and Core-2 do not have MCLAG configuration.
- B. Core-2 has the lowest bridge priority.
- C. port1 on Core-2 is discarding only management traffic.
- D. Access-1 is the root bridge and can only have one root port.
Answer: A
NEW QUESTION # 27
......
Fortinet NSE6_FSW-7.2 exam is a vendor-specific certification offered by Fortinet. It is a globally recognized certification that demonstrates the candidate's proficiency in FortiSwitches. NSE6_FSW-7.2 exam is available online and can be taken at any time from anywhere.
Ace Fortinet NSE6_FSW-7.2 Certification with Actual Questions Oct 29, 2024 Updated: https://www.prep4away.com/Fortinet-certification/braindumps.NSE6_FSW-7.2.ete.file.html
NSE 6 Network Security Specialist Certified Official Practice Test NSE6_FSW-7.2: https://drive.google.com/open?id=1axyb90tJHtaiMF143ZLbbMRjtDDHEvP5