[Oct-2024 Newly Released] D-PE-OE-23 Exam Questions For You To Pass [Q114-Q135]

Share

[Oct-2024 Newly Released] D-PE-OE-23 Exam Questions For You To Pass

EMC D-PE-OE-23 Exam: Basic Questions With Answers

NEW QUESTION # 114
A system engineer tried to remotely update the firmware of the PSUs on a PowerEdge 15G server, but the update failed.
An error message is received:
- PSU0006: Power supply X is incorrectly configured
What is the reason for the failure?

  • A. The server has only one PSU.
  • B. The firmware is incompatible.
  • C. PSUs are connected to different voltages.
  • D. A mixed PSU configuration exists.

Answer: D


NEW QUESTION # 115
A technician recently installed a supported third-party PCIe expansion card and updated the iDRAC firmware on a server. The server is now experiencing internal temperatures that are higher than normal.
A second technician is troubleshooting the server and discovers that the expansion card is hot to the touch.
What should the technician do to resolve this issue?

  • A. Replace the fans one at a time until the faulty fan is identified.
  • B. Reseat all the fans.
  • C. Adjust the power settings.
  • D. Adjust the Multi Vector Cooling values.

Answer: D


NEW QUESTION # 116
A technician deploys a server. The iDRAC was configured with a static IP address and hostname.
The technician can NOT ping the iDRAC from the workstation when using the hostname. The technician can ping the iDRAC with the IP address.
Which setting should the technician configure to fix the deployment?

  • A. In the iDRAC GUI, select the Reset DNS Cache option.
  • B. In the iDRAC GUI, select the Register DRAC on DNS option.
  • C. In the Lifecycle Controller, update the DNS Server value
  • D. In the Lifecycle Controller, update the DNS Server Name

Answer: D


NEW QUESTION # 117
What is the Open Compute Project (OCP) card used for in a Dell EMC PowerEdge server?

  • A. Consumes a PCIe slot
  • B. Removal of NDC
  • C. Provides a hot-swap component
  • D. Fixed network interconnect

Answer: B


NEW QUESTION # 118
A technician has the ISO image of an OS that they need to install on a server in a remote location.
They are already logged into the iDRAC.
How should the technician install the OS?

  • A. Click Launch under the Virtual Console Preview, Select Next Boot, and choose Virtual CD/DVD/ISO
  • B. Click Launch under the Virtual Console Preview and then connect to Virtual Media
  • C. Click on Update and Rollback under Quick Launch Tasks
  • D. Click Launch under the Virtual Console Preview, reboot the server into F10, and start the Lifecycle Controller OS Deployment wizard

Answer: D


NEW QUESTION # 119
A technician needs to install a server with a PERC RAID controller and 24, 2.5" SAS SED drives.
The installation requires the following items to be created:
- Three equal-sized virtual disks
- Encrypted virtual disks
- A global hot spare
In addition to selecting the physical drive to be the hot spare disk, what tasks should the technician perform to set up the RAID controller?

  • A. Boot to F12 and create the three virtual disks
    Select each physical drive and enable encryption
  • B. Boot to F12 and create the three virtual disks
    Select each virtual disk and enable encryption
  • C. Access the iDRAC GUI and create the three virtual disks
    Select each virtual disk and enable encryption
  • D. Boot to Ctrl+R and create the three virtual disks
    Select each physical drive and enable encryption

Answer: C


NEW QUESTION # 120
A technician needs to perform a RAID controller firmware update from within the Operating System.
The server runs Red Hat Enterprise Linux and is configured with an iDRAC basic license.
Which three steps should the technician take to complete this task? (Choose three.)

  • A. After the firmware update, restart the server
  • B. Restart the server and press F10 to start the firmware update process
  • C. Obtain the latest firmware update for the RAID controller
  • D. After firmware update, run fsck command on the virtual disks
  • E. Open a command shell and execute the firmware package
  • F. Run racadm fwupdate command from a management station

Answer: A,E,F


NEW QUESTION # 121
A technician is sent on- site to troubleshoot a server that produced an error message during the most recent POST but then completed the POST and booted to the operating system.
The user cannot remember the specific error and no entry was made in the error tog relating to this error.
How can the technician find out what the error message was?

  • A. Access the Lifecycle Controller and view the last boot cycle video capture entry
  • B. Reload the BIOS firmware
  • C. Export the Server profile and analyze tor any POST errors
  • D. Access the iDRAC and view the last boot cycle video capture entry

Answer: C


NEW QUESTION # 122
What is the minimum version of ESXi that should be used to avoid potential issues writing to the SD cards when running ESXi 7 from an IDSDM?

  • A. 7.0 U3c
  • B. 7.0 U2e
  • C. 7.0 U3g
  • D. 7.0 U2c

Answer: D


NEW QUESTION # 123
A user removes several Dell EMC PowerEdge servers from the production environment.
What can they use to reset the server in a secure manner?

  • A. Factory Reset menu in BIOS
  • B. Retire or Repurpose System function in Lifecycle Controller
  • C. Factory Reset menu in iDRAC
  • D. Retire or Repurpose System function in OpenManage Enterprise

Answer: B


NEW QUESTION # 124
What color is used to designate a hot-swappable component?

  • A. Yellow
  • B. Orange
  • C. Blue
  • D. Amber

Answer: B


NEW QUESTION # 125
What happened on April 30, 2019? Note: It is necessary to dose (x) the simulator window before you can select a response to this question.


  • A. Option D
  • B. Option B
  • C. Option C
  • D. Option A

Answer: C


NEW QUESTION # 126
Which Dell PowerEdge 16G server has the highest GPU density to run workloads like HPC, AI, DB Analytics, and VDI?

  • A. XR7620
  • B. XR4520c
  • C. XE8640
  • D. XE8545

Answer: C


NEW QUESTION # 127
A technician is tasked to perform a RAID Level Migration (RLM) of a RAID 5 array to a RAID 6 array.
They back up data and look in iDRAC Storage and find that the current RAID 5 array is sliced into two virtual disks.
What should the technician do to achieve the desired RAID level?

  • A. Use iDRAC GUI under Storage Configuration to delete the arrays and recreate the new RAID 6 array
  • B. Reboot and press Ctrl-R to complete RAID migration
  • C. Use SupportAssist Enterprise to complete RAID migration
  • D. Open the OpenManage Enterprise GUI, delete the arrays, and recreate the new RAID 6 array

Answer: A


NEW QUESTION # 128
A technician installs a NIC on a single CPU server. However, the NIC is not detected when they power on the server.
What should the technician verify to make sure that the NIC is detected correctly?

  • A. NIC is installed in an expansion slot managed by the single CPU
  • B. Network cable is plugged into the newly installed NIC
  • C. System Setup is set to BIOS boot mode
  • D. NIC driver is up to date

Answer: A


NEW QUESTION # 129
Starting from which Dell EMC PowerEdge server hardware generation is the Micro SD card in the IDSDM/vFlash module supported?

  • A. 12G
  • B. 11G
  • C. 13G
  • D. 14G

Answer: C


NEW QUESTION # 130
A Dell EMC PowerEdge server has been updated with an LCC and iDRAC DUP to the latest firmware when performing a firmware rollback?

  • A. The LCC can be rolled back; the iDRAC cannot be rolled back
  • B. The iDRAC cannot be rolled back and the LCC cannot be rolled back
  • C. Both the iDRAC and the LCC can be rolled back
  • D. The iDRAC can be rolled back; the LCC cannot be rolled back

Answer: C


NEW QUESTION # 131
A technician installs a server with a network daughter card (NDC). The NDC has two 10Gb BaseT ports as well as 1Gb BaseT ports. The technician is using the correct CAT- 6 network cable and a 10Gb switch. The server reports 1Gb connections on ports 3 and 4. Ports 1 and 2 are down.
How should the technician get 10Gb connectivity?

  • A. Hard set the switch ports to 10Gb
  • B. Replace the network cables
  • C. Use different ports on the switch
  • D. Move the cables over to ports 1 and 2

Answer: B


NEW QUESTION # 132
While working on a Dell EMC PowerEdge R640 server, a technician accidently removes two fans at the same time.
What should happen to the server?

  • A. Remaining fans increase RPM to compensate for the removed fans
    LCD changes to amber and displays an error message
    Server stays operational
  • B. Remaining fans increase RPM to compensate for the removed fans
    LCD changes to blue and displays an error description
    Server performs a controlled shutdown
  • C. Remaining fans stay at the recommended RPM
    iDRAC slows down the speed of the CPUs to avoid a temperature increase
    LCD changes to blue but an alert would have been sent out
  • D. Remaining fans increase RPM to compensate for the removed fans
    LCD changes to amber and displays an error message
    Server performs a controlled shutdown

Answer: A


NEW QUESTION # 133
A technician deploys a server. The iDRAC was configured with a static IP address and hostname.
The technician is not able to ping the iDRAC from the workstation when using the hostname. However, they can ping the iDRAC with the IP address.
Which setting should the technician configure to address the issue?

  • A. Register DRAC on DNS option in the iDRAC GUI
  • B. DNS Server value in the Lifecycle Controller
  • C. DNS Name in the Lifecycle Controller
  • D. Reset DNS Cache option in the IDRAC GUI

Answer: A


NEW QUESTION # 134
Which iDRAC feature requires the Enterprise license?

  • A. Customizable Security Banner
  • B. Boot and Crash Capture
  • C. SSD wear monitoring
  • D. iDRAC Direct

Answer: B


NEW QUESTION # 135
......

New 2024 Realistic Free EMC D-PE-OE-23 Exam Dump Questions and Answer: https://www.prep4away.com/EMC-certification/braindumps.D-PE-OE-23.ete.file.html

D-PE-OE-23 Practice Test Engine: Try These 325 Exam Questions: https://drive.google.com/open?id=191HZfWCHcXjWvanI0Bx9DNaQkmyv7Sxf