The HP HPE2-T37 Certification Exam is a web-based exam that tests the candidates' knowledge and skills in using HPE OneView software to manage and deploy infrastructure solutions. The exam consists of 60 multiple-choice questions that must be completed within 90 minutes. To pass the exam, candidates must score at least 70%.

 

NEW QUESTION # 34
Your customer is considering HPE Synergy as a hardware platform for visualization workload. The customer environment is wry dynamic, and they often have to modify hypervisor networking.
Which resource provided by HPE should you discuss with this customer?

  • A. HPE Image Streamer provides templates which can be updated to map the hypervisor requirements
  • B. PowerShell Library for HPE OneView allows scripted environment modification.
  • C. HPE OneView for VMware vCenter Server will enable host profile functionality and simplify changes.
  • D. HPE OneView Global Dashboard allows server profile replication and change management.

Answer: C


NEW QUESTION # 35
Within HPE OneView you can configure SNMPv1 read community string.
What is the purpose of this feature?

  • A. This is an SNMP community string that will be used when traps are forwarded to a WBEM Provider
  • B. This is an SNMP community string that will be used to receive a trap's SNMP Agent
  • C. This is an SNMP community string that will be used when traps are forwarded to other SNMP applications
  • D. This is an SNMP community string that will be used to receive traps from HPE Onboard Administrators

Answer: B


NEW QUESTION # 36
Which statement about the presented storage pools is true?

  • A. All storage pools from the system named ThreePAR-1 can be used for volume provisioning
  • B. All storage pools in managed state have a valid HPE OneView license applied
  • C. HPE OneView can be used to configure replication only between managed storage pools
  • D. Storage pools in discovered state can be removed from HPE OneView.

Answer: A


NEW QUESTION # 37
Which types of support dump can be created using HPE OneView? (Select two.)

  • A. Maintenance console support dump
  • B. Firmware deployment support dump
  • C. Logical enclosure support dump
  • D. Appliance support dump
  • E. Enclosure group support dump

Answer: C,D


NEW QUESTION # 38
Click option that will allow you to select a FlexNIC function for the specified connection.

Answer:

Explanation:


NEW QUESTION # 39
You are deploying HPE OneView to manage a customer's HPE ProLiant servers Is this statement about appliance availability true?

  • A. HPE OneView availability relies on HA features provoed by the hypervisor
  • B. During hpe oneView deployment customer may select configure proprietary HA mode.
  • C. HPE OneView has a built-in HA feature that can be activated with an additional license
  • D. HA features for HPE OneView are enabled only if the appliance is deployed on an HPE SimpliVity cluster

Answer: A


NEW QUESTION # 40
You want to put two FlexNlCs into a single Link Aggregation Group within a server profile. What Is a prerequisite for this setup?

  • A. The sFlow option must be enabled and configured.
  • B. Both FlexNlCs must be connected to the same network.
  • C. The Compute Module profile must have exactly two connections defined.
  • D. An upgrade license must be purchased and deployed.

Answer: A


NEW QUESTION # 41
As a part of troubleshooting, you have to reinstall the same version of the firmware on an HPE Synergy Compute Module. Click the area within the Firmware section of the server profile that will allow you to install the same firmware version.

Answer:

Explanation:


NEW QUESTION # 42
Which statement about logical JBODs configured using KPE OneView and D3940 Storage Modules is true?

  • A. Different types of the drives can be used within a logical JBOD as long as they have the same capacity
  • B. A logical JBOD lifecycle can be associated with a server profile lifecycle and drives can be securely erased.
  • C. A logical JBOD cannot be created during server profile creation and must be prepared in advance
  • D. Logical JBOD functionality must be enabled on the Enclosure Group level by a storage administrator

Answer: C


NEW QUESTION # 43
What is required to add remote frame link topology to HPE OneView?

  • A. Management ports of the remote frame link topology must be connected to the management LAN.
  • B. The HPE OneView certificate from the primary site must be added to HPE OneView in the remote site.
  • C. The IP address assigned to HPE Composer installed in a remote site must be registered in a primary site.
  • D. Multi-site licenses must be added to HPE OneView and activate for all available HPE Synergy frames.

Answer: A


NEW QUESTION # 44
You have created volumes using array management tools and imported the volumes to HPE OneView.
Which statement about these volumes is true?

  • A. Volumes imported to HPE OneView cannot be removed using the HPE OneView interface
  • B. Volumes imported to HPE OneView is managed just like a volume created using HPE OneView
  • C. Imported volumes are treated as private volumes and can be only used boot volumes
  • D. A snapshot for imported volumes can be ceated only by using array management tools

Answer: D


NEW QUESTION # 45
Refer to the exhibit.

Which statement about server connections is true?

  • A. Storage array is connected directly to an HPE Synergy frame
  • B. LACP on downlinks is configured for Ethernet connection
  • C. Ethernet connection is configured to boot from PXE
  • D. All connections within the server profile are using physical IDs

Answer: C


NEW QUESTION # 46
Refer to the exhibit.

Which statement about the logical interconnect shown is true?

  • A. The maximum supported number of the internal networks for logical interconnect is configured.
  • B. FC uplinks are not supported and will be converted to FCoE or RoCE uplinks.
  • C. Additional uplink ports can be added to ETH-Uplink to increase available bandwidth.
  • D. For FC uplink sets, an additional uplink from second module should be added for redundancy.

Answer: B


NEW QUESTION # 47
Which operation can be performed using HPE OneView for VMware vCenter Server?

  • A. Configure VMware cluster properties tor HA and DRS
  • B. Create a new VMware cluster within vCenter Server
  • C. Remove a new node from an existing cluster
  • D. Create a new distributed switch for cluster connectivity

Answer: C


NEW QUESTION # 48
For HPE Primera, match each task with the management tool that can be used to perform it.

Answer:

Explanation:


NEW QUESTION # 49
You are creating a Logical Interconnect Group (LIG) that will be used to configure SAS connectivity. What is the maximum number of frames that can be inducted in this LIG?

  • A. 4 frames
  • B. 2 frames
  • C. 5 frames
  • D. 3 frames
  • E. 1 frame

Answer: E


NEW QUESTION # 50
Your customer built a sever profile for HPE Synergy Gen 10 server and configured boot mode to Legacy BIOS. Which feature Is not available for this Compute Module?

  • A. BIOS management
  • B. Boot from SAN
  • C. Workload profile
  • D. Secure boot

Answer: D


NEW QUESTION # 51
Your customer plans to use HPE OneView to manage a small environment based on HPE ProLiant servers that includes G7 and Gen 10 systems. What should you explain to this customer?

  • A. HPE ProLiant G7 and Gen10 cannot be managed using the same appliance.
  • B. HPE Management Agent must he installed for for HPE ProLiant Gen 10 servers.
  • C. HPE ProLiant Gen 10 servers do not need an HPE OneView license.
  • D. Not all of the features will be available for HPE ProLiant G7 systems.

Answer: C


NEW QUESTION # 52
Refer to the exhibit.

Your customer wants to define a Logical Interconnect Group (UG) and set the redundancy of the master modules to highly available, but this option is not available. What is a possible reason?

  • A. Firmware on the master modules is too low to support highly available setup.
  • B. A dedicated license must be added to HPE OneView to enable this feature.
  • C. There are not sufficient frames for highly available setup.
  • D. Some master modules only support a redundant setup.

Answer: D


NEW QUESTION # 53
You Just downloaded a logical enclosure support dump, but you cannot extract files from the downloaded support dump. What is a likely cause of the issue?

  • A. The backup user role must be used to extract the support dump
  • B. The support dump does not have a valid HPE OneView certificate
  • C. The support dump is encrypted and cannot be unpacked
  • D. The support dump for Logical Enclosure can be analyzed only using special tool.

Answer: D


NEW QUESTION # 54
Your customer wants to use HPE OneView for VMware vCenter Server to simplify management of their VMware cluster running on HPE Synergy. The customer is concerned with the cost of additional licenses.
How will you explain licensing rules for this product?

  • A. As long as the server is managed using HPE OneView. the customer can use HPE OneView for VMware vCenter Server without additional licenses.
  • B. As long as the customer has HPE OneVtew Global Dashboard deployed, HPE OneView for VMware vCenter Server does not require any additional licenses.
  • C. One HPE OneView for VMware vCenter Server license is required per HPE Synergy frame if more than
    10 Compute Modules are installed in the frame.
  • D. If the number of the HPE Synergy Compute Modules installed in HPE Synergy frame is less than 10, no license is required to use HPE OneView tor VMware vCenter Server.

Answer: C


NEW QUESTION # 55
......

HPE2-T37 Exam Questions and Valid HPE2-T37 Dumps PDF: https://www.prep4away.com/HP-certification/braindumps.HPE2-T37.ete.file.html

HPE2-T37 Brain Dump: A Study Guide with Tips & Tricks for passing Exam: https://drive.google.com/open?id=1uwZNcgigg8bzfRN6QF1bgDgP8E3TXCsd