[Aug 30, 2021] 500-920 PDF Dumps is essential on your 500-920 Exam Questions Certain Success! [Q23-Q41]

Share

[Aug 30, 2021]  500-920 PDF Dumps is essential on your 500-920 Exam Questions Certain Success!

500-920 PDF Questions - Perfect Prospect To Go With 500-920 Practice Exam

NEW QUESTION 23
When troubleshooting a LAN connectivity issue, you notice a failed uplink from the Cisco UCS Fabric Interconnects to the upstream LAN switch. What two could be causing the issue? (Choose two )

  • A. Misconfigured QoS parameters on the failed uplink
  • B. A port channel mismatch between the Fabric Interconnects and the upstream LAN switch
  • C. A SFP Type mismatch between the Fabric Interconnects and the upstream LAN switch
  • D. A port speed configuration mismatch between the Fabric Interconnects and the upstream LAN switch
  • E. Misconfigured VLAN on the failed uplink

Answer: A,B

 

NEW QUESTION 24
Which are two Application Gateways primary roles? (Choose two )

  • A. Automate updates to the XML Database
  • B. Communicate with end points and report their health and state
  • C. Manage configuration changes during FSM transitions
  • D. Manage configuration changes made with UCS Manager
  • E. Communicate with virtual machines and report health and state

Answer: A,C

 

NEW QUESTION 25
When troubleshooting UCS initialization issues that require Fabric Interconnect reboots, which Fabric Interconnect should be rebooted first?

  • A. The subordinate Fabric Interconnect
  • B. The Cisco UCS Manager will determine with Fabric Interconnect to reboot
  • C. The primary Fabric Interconnect
  • D. Both Fabric Interconnects must be rebooted simultaneously

Answer: C

 

NEW QUESTION 26
A Hard Drive (HDD) has been hot swapped in a UCS server blade, however, the UCS Manager GUI is not displaying updated metrics about the replacement drive. What action will be required to properly display updated metrics?

  • A. Remove and re-insert the server blade HDD controller mezzanine card
  • B. Use the CLI, since HDD metrics cannot be displayed with the UCS Manager GUI
  • C. Reboot the server.
  • D. Reboot the Fabric Interconnects

Answer: A

 

NEW QUESTION 27
What is the result of enabling the Core File Exporter in UCS Manager?

  • A. A core dump file will be immediately created and transmitted using HTTP protocol
  • B. A core dump must be remotely activated by Cisco TAC.
  • C. A core dump will immediately be generated and will be exported
  • D. If a subsequent triggering event occurs, a core dump will be generated and sent by TFTP

Answer: C

 

NEW QUESTION 28
Which two ports on a pair of Cisco Fabric Interconnects must be properly cabled for the pair to form a cluster? (Choose two )

  • A. L2 > L1
  • B. L1 > L1
  • C. L2 > L2
  • D. L1 > L2

Answer: B,C

 

NEW QUESTION 29
When configuring UCS SAN Connectivity to a 3rd Party FibreChannel Storage Array that is connecting directly to the UCS Fabric Interconnects, which option is Cisco recommended'?

  • A. Connect the Storage Array to a RC Storage Port and Enable NPV Mode on the UCS Fabric Interconnects
  • B. Connect the Storage Array to an Appliance Port and Enable NPV Mode on the UCS Fabric Interconnects
  • C. Direct connectivity between UCS Fabric Interconnects and FibreChannel Storage Arrays is not supported
  • D. Connect the Storage Array to a FC Storage Port and Enable Switching Mode on the UCS Fabric Interconnects
  • E. Connect the Storage Array to an Appliance Port and Enable Switching Mode on the UCS Fabric Interconnects

Answer: D

 

NEW QUESTION 30
Which command sequence is required to reset Cisco Integrated Management Controller (IMC) of a Cisco UCS Server?

  • A. connect cimc | reset | commit
  • B. connect cimc | reset | validate
  • C. scope cimc | reset | commit-buffer
  • D. scope cimc | reset | validate

Answer: C

 

NEW QUESTION 31
What three options should be verified, when you are able to connect to Cisco UCS Manager, but unable to open a KVM session to a blade? (Choose three)

  • A. Verify the KVM IP Address is on the same subnet as the Fabric Interconnect management address
  • B. Confirm the IP Address assigned to the KVM is not a duplicate IP
  • C. Confirm the KVM IP Address is added to the route table in Cisco UCS Manager
  • D. Confirm the IP Address assigned to UCS Manager is the same as the KVM address
  • E. Verify TCP port 2068 is not blocked by an ACL or Firewall
  • F. Verify the KVM IP Address is on the same ip subnet as the virtual machines

Answer: B,C,E

 

NEW QUESTION 32
Which Cisco UCS internal component maintains the UCS XML database, manages the FSM stages and operations and instructs the Application Gateway to perform operations on physical and logical elements?

  • A. Cisco UCS Manager
  • B. Cisco Application Gateways
  • C. Cisco Data Management Engine
  • D. Cisco Finite State Machine

Answer: C

Explanation:
Reference:
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/ucs-manager/GUI-User-Guides/System-Monitoring/3-1/b_UCSM_GUI_System_Monitoring_Guide_3_1/b_UCSM_GUI_System_Monitoring_Guide_3_1_chapter_0100.html

 

NEW QUESTION 33
You are in the process of upgrading your UCS M3 Server to a newer UCS M4 Server. You associate the Service Profile to the new UCS Server, but it fails to boot You suspect of a failed boot hard drive. You check your RAID1 Boot LUN in UCS Manager, but see no error messages What could be causing the issue?

  • A. A misconfiguration on the Service Profile Local Disk Policy
  • B. A misconfiguration on the Service Profile Local Boot Policy
  • C. The newer Cisco UCS M4 Server is using flash drives, not hard drives
  • D. The newer Cisco UCS M4 Server is using disks of larger capacity than the previous UCS M3 Server

Answer: C

 

NEW QUESTION 34
Which statement is true regarding the UCS Manager GUI is showing "Overall Status Unassociated" in the General tab for a C-series server?

  • A. The server does not have a service profile assigned, but has been discovered by UCS Manager
  • B. The server has a service profile assigned, but has connectivity issues with UCS Manager
  • C. The server is not properly connected
  • D. The server has been properly connected, but has not been discovered by UCS Manager

Answer: C

 

NEW QUESTION 35
Which statement regarding the UCS C-senes connectivity modes best describes connectivity options in a UCS Manager integrated environment?

  • A. All UCS C-series servers in a single UCS Manager domain must share the same connectivity model
  • B. UCS C-series servers may be connected with or without the use of Fabric Extenders (FEX) in environments running UCS Manager Software Release 2 2 or later
  • C. UCS C-series servers must be connected to Fabric Interconnects using Fabric Extenders (FEX)
  • D. UCS C-series servers may be connected to multiple UCS Manager domains at the same time

Answer: B

 

NEW QUESTION 36
Which statement is true when using SPAN for Fibre Channel (FC) Traffic?

  • A. FC port on Cisco UCS 6238UP can be used as a SPAN source
  • B. When defining FC uplink port as the SPAN destination, system will automatically stop using that port as an uplink port
  • C. Any port can be used as a SPAN destination port Even if it is defined as Eth uplink port it will be automatically converted to FC uplink port
  • D. For FC SPAN sessions we do not have to specifically enable the monitoring session

Answer: A

 

NEW QUESTION 37
When it comes to pinning vNIC traffic from a UCS Server to the Fabric Interconnect uplink what configuration can you perform?

  • A. You can configure Static Uplink Pinning. If an uplink interface fails on one Fabric Interconnect, the server will fail to the first available uplink on the same Fabric Interconnect
  • B. You can configure Static Uplink Pinning. If an uplink interface fails on one Fabric Interconnect, the server will fail to the first available uplink on the other Fabric Interconnect
  • C. You can configure Automatic Uplink Pinning. If an uplink interface fails on one Fabric Interconnect the server will fail to the matching uplink on the other Fabric Interconnect
  • D. You can configure Automatic Uplink Pinning. If an uplink interface fails on one Fabric Interconnect, the server will fail to the first available uplink on the other Fabric Interconnect
  • E. You can configure Static Uplink Pinning. If an uplink interface fails on one Fabric Interconnect the server will fail to the matching uplink on the other Fabric Interconnect

Answer: D

 

NEW QUESTION 38
What is the likely cause of an intermittent SAN Boot fails?

  • A. LUN ID Mismatch
  • B. FCoE used instead of FC
  • C. Misconfigured SAN boot target in the boot policy of the service profile
  • D. Wrong boot order in the service profile

Answer: C

 

NEW QUESTION 39
......

500-920 Exam with Accurate Cisco Data Center Unified Computing Infrastructure Troubleshooting PDF Questions: https://www.prep4away.com/Cisco-certification/braindumps.500-920.ete.file.html